Skip to main content

Table 6 Uniaxial tensile test results for healthy and aneurysmal aortas, from the references

From: Metamaterial design for aortic aneurysm simulation using 3D printing

Reference

Healthy / Aneurysm

Orientation

Max Stress [MPa]

Strain @ max stress [%]

   

\(\mu \pm \sigma\)

CoV

\(\mu \pm \sigma\)

CoV

Forsell et al. (2014) * [37]

Ascending TAA

Circ.

0.486 ± 0.21

0.43

52.11 ± 0.13 **

0.002

Forsell et al. (2012) [38]

AAA

Long.

0.437 ± 0.319

0.73

32.5 ± 11.3 **

0.35

Maizato et al. (2023) *** [39]

HT

Circ.

0.76 ± 0.23

0.30

57.18 ± 7.96

0.14

Reeps et al. (2012) [40]

AAA

Circ.

1.063 ± 0.49

0.46

-

-

Vallabhaneni et al. (2004) [41]

AAA

Long.

0.53 ± 0.02

0.04

30 ± 2

0.07

 

HA

Circ.

0.61 ± 0.07

0.11

29 ± 4

0.14

 

HA

Long.

1.30 ± 0.11

0.08

33 ± 4

0.12

  1. \(\mu\) – Mean, \(\sigma\) – Standard deviation, CoV – Coefficient of Variation, TAA – Thoracic Aortic Aneurysm, AAA – Abdominal Aortic Aneurysm, HA – Healthy Abdominal aorta, HT – Healthy Thoracic aorta, Circ – Circumferential, Long – Longitudinal. * Data retrieved from supplementary material document. ** Data given as relative stretch, adapted to strain. *** Mean from two aortas, with three samples each