Table 3 Average score of confidence for each step of training with the idealised model and the anatomical model. P values compare scores between idealised and anatomical models

From: Effectiveness of a new 3D printed simulator for mitral transcatheter edge-to-edge repair in enhancing the confidence and procedural skills of the operator

Steps of the m-TEER procedure

Idealised model

Anatomical model

T-test P values

Transseptal crossing

3.3 (± 0.91)

3.5 (± 0.72)

0.43

Steering clip in LA

3.6 (± 0.78)

3.9 (± 0.78)

0.10

Positioning trajectory of the clip

3.6 (± 0.98)

3.9 (± 0.78)

0.33

Recognising area of interest on MV

3.4 (± 1.2)

4.0 (± 0.87)

< 0.01

Assessing position of clip above valve

3.6 (± 0.78)

4.1 (± 0.75)

< 0.01

Assessing orientation of clip above valve

3.6 (± 0.86)

4.1 (± 0.80)

0.01

Grasping leaflets

3.7 (± 0.71)

4.2 (± 0.73)

0.46

closing a clip

4.0 (± 0.69)

4.2 (± 0.90)

0.46

Re-opening clip and re-positioning

3.6 (± 0.78)

4.1 (± 0.86)

< 0.01