Your privacy, your choice

We use essential cookies to make sure the site can function. We also use optional cookies for advertising, personalisation of content, usage analysis, and social media.

By accepting optional cookies, you consent to the processing of your personal data - including transfers to third parties. Some third parties are outside of the European Economic Area, with varying standards of data protection.

See our privacy policy for more information on the use of your personal data.

for further information and to change your choices.

Skip to main content

Table 4 Parameters Th, Ti, Fi, Nu, mean values and ICCs. mean all: mean value across all observers and cases, min/max mean: min/max mean values per observer, ICC: intra class correlation coefficient, CI: confidence interval

From: Accuracy of pelvic bone segmentation for 3d printing: a study of segmentation accuracy based on anatomic landmarks to evaluate the influence of the observer

     

ICCa 95% CI

parameter

mean all

min mean

max mean

ICCa

lower limit

upper limit

Th [HU]

170.1

154.6

200

0.194

0.012

0.475

Ti [min]

71.4

46.5

110.4

0.108

-0.016

0.354

Fi [kB]

37,771.8

36,038.9

40,242.7

0.702

0.469

0.880

Nu

773,611

738,065

824,387

0.703

0.469

0.880

  1. aTwo-way random effects, absolute agreement, single rater/measurement